Transitioning Back To Life
When an every-moment-counts situation occurs in emergency treatment, you need to do everything possible in your power to save a patient’s life. The EMS-1052K is a light and compact device that enables you to deliver a fast response to the patient on site.
Nihon Kohden’s original innovative technology contributes to a better outcome for the patient and the integrated system for data transmission empowers your team to improve the quality of resuscitation.
cap-ONE
Nihon Kohden's cap-ONE is the world's smallest and lightest mainstream CO² sensor. It is suitable for emergency sites because of the simple heater-less design.
This CO² sensor has a fast response which is helpful to confirm tracheal tube position, ensure quality of CPR and be an early indicator for Return of spontaneous circulation (ROSC) during CPR as recommended by international guidelines.
Proper depth of chest compressions during CPR creates adequate blood flow and oxygen delivery to the heart and brain. Moreover, proper rate of chest compressions during CPR is an important determinant of ROSC and survival with good neurologic function.
Minimize pause during CPR
Nihon Kohden's artifact suppression pads,P-700 series, are less affected by baseline drift during CPR compared to conventional pads. They minimize the CPR pause period, as ECG waveforms can be seen even under chest
compressions.
Faster shock
It takes less than 4 seconds to charge 200J with a fully charged new battery. Faster charging time helps you deliver energy quickly when VF is observed. ECG baseline recovers within 3 seconds after defibrillation. The defibrillation result and patient condition can be monitored immediately.
AED Mode
Continuous VF/VT analysis is available on cardiolifeEMS. With this function, the ECG waveform can be analyzed during CPR and energy charging starts before the shock is advised. This helps you deliver faster defibrillation in AED mode than ever before.
ActiBiphasic
It is important for effective defibrillation to deliver all the necessary energy to the patient within 20 ms.Nihon Kohden’s unique ActiBiphasic technology keeps the 2nd phase duration within 4 ms. This reduces total energy delivery duration to close to 20 ms even in high impedance patients.
Post Cardiac Arrest Management
cardiolifeEMS provides you with advanced ECG diagnosis for STEMI patients with additional 6-lead information for posterior and right ventricular leads by using synthesized 18-lead ECG, synECi18.
Real time data transmission supports sharing the current patient condition with your team to enable the patient to be treated by various specialists during transportation.
Data Transmission
- Real time data transmission supports sharing the current patient condition with your team to enable the patient to be treated by various specialists during transportation.
- Vital sign data(Real time) Vitrac
- Data acquisition (after transportation)
12-lead ECG measurement with synthesized 18-lead
With synthesized 18-lead ECG (synECi18)*, by just measuring 12-lead ECG, you can get additional information for both right ventricular and posterior leads. It helps you identify invisible ischemia.